Motor Control Board Diagnostics
SmartControl
The SmartControl contains stored data to assist with
troubleshooting and maintenance. To view this stored
data on the digital display:
1. Relieve pressure, page 9.
2. Plug in sprayer.
3. Hold down display button and turn sprayer ON.
Data Point
Definition
1
Number of hours power switch has been ON with power applied. (Pro 230ES only)
Serial Number of sprayer. (Pro 270ES only)
2
Number of hours motor has been running.
3
Last error code. Press and hold display button to clear error code to E=00
4
Software revision
32
4. Release display button about 1 second after turning
on sprayer.
Pro 230ES displays (model family) for a few sec-
onds and then data point 1 is displayed.
5. Push display button and next data point displays.
6. Turn sprayer OFF and then ON to exit stored data
mode.