Declaration Of In- And Output - Parker Compax3S025V2 Manual

C3 i20 t11 controlmanager
Hide thumbs Also See for Compax3S025V2:
Table of Contents

Advertisement

DBX4.1
bChangeSetImmediate
DBX4.2
bStartHoming
DBW6
nLaddr
DBD8
iPosition
DBD12
iVelocity
DBD16
iAcceleration
DBD20
iDeceleration
DBD24
iInPosWindowAbs
DBW28
nCmd
DBW30
nPNUIndex
DBW32
nPNUSubindex
DBD34
iParameterValue
DBD38
TonTimer1
DBD42
TonTimer2
DBX56.0 Word 4
stC3PKWInDint.nPKE
DBX72.0 Word 7
stC3PZDIn.nStatus

3.4.2 Declaration of In- and Output

Parameter
Declaratio
n
bAbsoluteRelative
IN
bEnable
IN
bExDataTransfer
IN
bFaultReset
IN
bHold
IN
bJogN
IN
bJogP
IN
bPositionResetMode
IN
bStop
IN
bChangeSetImmediate
IN_OUT
bStartHoming
IN_OUT
bStartPositioning
IN_OUT
bCommErr
OUT
Klaus Zimmer
Parker Hannifin GmbH & Co KG
EME - Electromechanical Automation Europe
Postfach 17 20 * 77607 Offenburg
Robert-Bosch-Straße 22 * 77656 Offenburg
E-Mail:
klaus_zimmer@parker.com
Electromechanical Automation
Product Management & Application
Data type
description
BOOL
=0 absolute, =1 relative movement
BOOL
=1 energise
=0 disenergize with AUS3 - Ramp (Not-Stop)
BOOL
=0 internal DP interface with SFC14/15 (internal Master in S7 CPU)
=1 external DP interface with FC2/FC1 (external Master CP 342-5)
BOOL
Acknowledge with rising edge, after that it is necessary to activate
energise <bEnable> (caused by the edge dedection it is needed to be set
to 0 first)
BOOL
=1 Temporary stop (the movement function is still available), =0 continue
BOOL
manual negative: JOG – movement within positioning end limits as long
as true
BOOL
manual positive: JOG – movement within positioning end limits as long as
true
BOOL
=0 Normal-, =1 Reset mode selected (in C3Mgr \\ I20T11 drive
Configuration \units... positioning reset distance and positioning reset
distance denominator is different from 0
BOOL
=1 Stop (movement function cancelled)
BOOL
With the Rising edge, a new position profile is activated;
<bChangeSetImmediate> is rested from the block itself. This command is
acknowledged from the block with <bPosRunning>. A new command is
also accepted if the actual movement is not finished (<bInPosition> =1).
BOOL
rising edge starts referencing movement, if permitted, neg. edge stops
referencing movement,
bStartHoming may only be reseted with <bHomingAttained>.
BOOL
With the Rising edge a new position profile is activated,
<bChangeSetImmediate> is reseted from the block itself. This command is
acknowledged from with <bPosRunning>. A new command is not accepted
if the actual movement is not finished (<bInPosition> =1).
BOOL
=1 Communication failure wit C3 (Failure from SFC14 / SFC15) (all other
messages are invalid)
C3 I20 T11 ControlManager application note eng.doc
Seite 9 von 20
Version: 16
stRd.iPositionValue
stRd.iVelocityValue
stRd.nActualError
bTransErr
iParameterValue
stC3PKWOutDint.nPKE
stC3PZDOut.nControl
11.02.2008
DBD46
DBD50
DBW54
DBX3.1
DBD34
DBX64.0 Word 4
DBX86.0 Word 7

Advertisement

Table of Contents
loading

Table of Contents