Sequence Of Process Data - Parker Compax3S025V2 Manual

C3 i20 t11 controlmanager
Hide thumbs Also See for Compax3S025V2:
Table of Contents

Advertisement

Parameter
Declaratio
n
bDriveErr
OUT
bEnabled
OUT
bHomingAttained
OUT
bHomingErr
OUT
bHomingRunning
OUT
bInPosition
OUT
bPosErr
OUT
bPosRunning
OUT
bTransErr
OUT
iAcceleration
STATIC
iDeceleration
STATIC
iInPosWindowAbs
STATIC
iParameterValue
STATIC
iPosition
STATIC
iVelocity
STATIC
stRd.iPositionValue
STATIC
stRd.iVelocityValue
STATIC
nCmd
STATIC
nPNUIndex
STATIC
nPNUSubindex
STATIC
TonTimer1
STATIC
TonTimer2
STATIC
nLaddr
STATIC
stRd.nActualError
STATIC
stC3PKWInDint.nPKE
STATIC
stC3PKWOutDint.nPKE
STATIC
stC3PZDIn.nStatus
STATIC
stC3PZDOut.nControl
STATIC

3.4.3 sequence of process data

3.4.3.1 settings of the static Operands at the Block
1. <nLaddr>
-
Parameter from HW Config: the first Start address of the C3 -Slave at the
PROFIBUS.
Klaus Zimmer
Parker Hannifin GmbH & Co KG
EME - Electromechanical Automation Europe
Postfach 17 20 * 77607 Offenburg
Robert-Bosch-Straße 22 * 77656 Offenburg
E-Mail:
klaus_zimmer@parker.com
Electromechanical Automation
Product Management & Application
Data type
description
BOOL
=1 failure from C3 (device / Motor)
BOOL
=1 Axis energised
=0 Axis nit energised
BOOL
=1 Reference ok.
BOOL
=1 watchdog/ timeout for Reference -run (occasionally TonTimer2 correct)
BOOL
=1 Reference run active
BOOL
=1 Axis in target position
BOOL
=1 watchdog timeout for Position -order (occasionally. TonTimer1 correct)
BOOL
=1 position or active
BOOL
=1 Format-, commando failure at transfer from / to C3
DINT
acceleration in U32 -Format (integer)
DINT
deceleration in U32 -Format (integer)
<iDeceleration> is transmitted throw the PKW channel in the case of a
change.
DINT
Position window in C4_3 Format (3 decimal places in two word integer),
additional monitoring of <bInPosition> with absolute positioning. the actual
position value is compared with the position set value. That is only possible
with absolute positioning (<bAbsoluteRelative> = false) and position Reset
mode (<bPositionResetMode> = false) is not activated (e.g. default value
= 1000 equal 1 u; u = dimension at C3 Mgr Increments, mm, Degrees,
Inch).
DINT
ProfiDrive Parameter Transfer value (source and destination) - write-/read
value of the Parameters, with INT-/WORD -Format only one word used.
DINT
target position / Distance in C4_3-Format (3 decimal places)
DINT
speed in C4_3-Format (3 decimal places)
DINT
actual position in C4_3-Format (3 decimal places)
DINT
Istgeschwindigkeit in C4_3-Format (3 decimal places)
INT
ProfiDrive-Parameter Transfer: command:
1 read
2 write WORD
3 write DWORD
INT
ProfiDrive-Parameter Transfer: PNU-Index
INT
ProfiDrive-Parameter Transfer: PNU - Subindex (incremented by one for
DPV0 done)
TIME
time value for timeout of Positioning
TIME
time value for timeout Reference run
WORD
= 0100
(=256
hex
dez
<bExDataTransfer> = true here it is required: 0000hex (=0dez).
WORD
Actual Failure (see C3 - Manual
) in WORD - Format
=1 no Error!
Word 4
Local PKW - input area for external CP
Word 4
Locals PKW - output area for external CP
Word 7
Localise PZD - input area for external CP
Word 7
Locales PZD - output area for external CP
C3 I20 T11 ControlManager application note eng.doc
Seite 10 von 20
Version: 16
) Start address C3-Slave out of SIMATIC HW Config, if