[PROFIBUS – operation mode]
Positioning
[PLC -> Compax3]
CW 1
Commanded positioning value (XCOMMANDED_A)
Commanded motion speed D (32 Bit)
Commanded acceleration B (32 Bit)
[Compax3 -> PLC]
SW 1
Actual position value XACTUAL_A
Actual speed value NACTUAL_B (32 Bit)
[Operation Mode Settings]
Acyclic process data channel / Parameter channel
Select with "PKW"
Error response on fieldbus failure is up to user.
\\ I20T11 drive configuration \ I/O - assignment
Selection:
It is recommend to select „free". With „Fixed assignment" are used some Binary
connections between control word and digital inputs (E0 ... E3), that cases if there is no
plug at X12 the C3 is not possible to be controlled.
3.2