Dual Wiegand Reader Door Configuration; Single Wiegand Reader Doors Configuration - Siemens SiPass integrated Controller And Device Installation Manual

Hide thumbs Also See for SiPass integrated:
Table of Contents

Advertisement

Access Controllers
2
ACC-AP

2.3.3.5 Dual Wiegand Reader Door Configuration

2.3.3.6 2 Single Wiegand Reader Doors Configuration

22 | 38
Label on AP Controller
IN 1
IN 2
IN 3
IN 4
RLY 1
RLY 2
OUT 1
OUT 2
OUT 3
OUT 4
READER 1
READER 2
Label on AP Controller
IN 1
IN 2
IN 3
IN 4
RLY 1
RLY 2
OUT 1
OUT 2
OUT 3
OUT 4
READER 1
READER 2
This configuration is not compatible with ACC-APM 12V/24V PSU Kit because IN
3 is pre-wired for power monitoring, and IN4 for cabinet tamper.
SiPass Point Function
REX
D/C
In 1
In case of ACC-APM 12V/24V PSU Kit, the pre-wiring is
already done for power monitoring.
In 2
In case of ACC-APM 12V/24V PSU Kit, the pre-wiring is
already done for cabinet tamper.
Door 1 LK
Out 1
Green LED for Reader 1
Red LED for Reader 1
Green LED for Reader 2
Red LED for Reader 2
Pins A and B of READER 1 port are the data lines for
Wiegand Reader 1. D1 = A; D0 = B
Pins A and B of READER 2 port are the data lines for
Wiegand Reader 2. D1 = A; D0 = B
SiPass Point Function
Door 1 REX
Door 1 D/C
Door 2 REX
Door 2 D/C
Door 1 LK
Door 2 LK
Green LED for Reader 1
Red LED for Reader 1
Green LED for Reader 2
Red LED for Reader 2
Pins A and B of READER 1 port are the data lines for
Wiegand Reader 1. D1 = A; D0 = B
Pins A and B of READER 2 port are the data lines for
Wiegand Reader 2. D1 = A; D0 = B
A6V11164550

Advertisement

Table of Contents
loading

Table of Contents