Download Print this page

Nahita 601/3 User Manual

Thermostatic water baths

Advertisement

Quick Links

Models: 601/3 – 601/5 – 601/12 – 601/19
Nahita Thermostatic Water Baths
User's Manual
Version 1, May 2020

Advertisement

loading

Summary of Contents for Nahita 601/3

  • Page 1 Models: 601/3 – 601/5 – 601/12 – 601/19 Nahita Thermostatic Water Baths User’s Manual Version 1, May 2020...
  • Page 2: Product Description

    PRODUCT DESCRIPTION Electric heating constant temperature water bath boiler is mainly used for distillation, desiccation, concentration and warm maceration of chemicals or biologics, it’s conventional indispensable instruments prepared in laboratories by various universities and colleges, secondary specialized schools, scientific research enterprises and institutions. PRODUCT STRUCTURE This product adopts water-trough liner which is one shot shock and extrusion using imported stainless steel and its shell is made of high-quality cold rolled...
  • Page 3 TECHNICAL PARAMETERS Model - Code 601/3 – JDD001 601/5 – JDD002 601/12-JDD003 601/19-JDD004 Controller Voltage 220V/50Hz 110V/60Hz Power(W) 300W 600W 800W 1200W Tem-range(℃) RT.+5~100℃ Temperature 0.1°C resolution Temperature ≤±0.5°C fluctuation Division accuracy ≤±1°C Timer Continuous mode / 9999 minutes Overcurrent protection; Over temperature alarm; Prevent dry burning...
  • Page 4 2-1. Indicator light function 1) AUT:It flickers during self-tuning, it is not bright in any other state. 2) OUT:It is bright when heating output. 3) ALM:It is bright when there is a temperature alarm. 4) TIM:It is bright when time is set, it flickers in the process of timing. 2-2.
  • Page 5 When the time is set to "0000", it indicates the timer is inoperative, the controller will run continuously, the under window will display the temperature set point value. If there is time set, the under window displays the running time, its decimal point and the “TIME”...
  • Page 6 under window displays "0", change "0" to "1" by pressing the “INC” button, then press the “SET” button, the controller will run the auto-tuning program, the “AUT” indicator flickers. After auto-tuning end, the indicator stops flickering, PID parameter value is saved automatically. In the auto-tuning process, press the “SHIFT” button for another 6 seconds, the controller will stop the auto-tuning program.
  • Page 7 Temperature It is usually used to correct errors (-999~999) slope in high temperature measurement. correction PK = 1000 × (Actual value – PV) ÷ PV Parameter table 2 (Setting range) Prompt Name Function description Factory value Password When “Lc=9”, enter next parameters.
  • Page 8 Parameter table 3 (Setting Prompt Name Function description range) Factory value When “Lc=567”, enter the next Password key parameters. Factory reset 0: cancel; 1: confirm (0~1) 0 6. Wiring ※ Common Failures and Troubleshooting Failure Cause Handling method Bad contact between plug and Replace the plug or socket tube.
  • Page 9 ※ Storage and Transport 1.This product shall be stored in a cool and dry environment with the temperature of -20℃~+40℃. 2.During handling, violent vibration and collision are strictly forbidden. Also, dampness shall be prevented. ※ Packing list 1.Main machine x1 pc 2.Power cable x1 pc 3.Stainless steel lid x1 pc 4.User manual x1 pc...

This manual is also suitable for:

601/5601/12601/19Jdd001Jdd002Jdd003 ... Show all