Servicing The Tool; Maintenance Frequency; Nose Equipment; Daily Servicing - Stanley ProSet XT1 Blind Rivet Tool Instruction Manual

Hydro-pneumatic power too
Hide thumbs Also See for ProSet XT1 Blind Rivet Tool:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
ENGLISH

5. SERVICING THE TOOL

5.1 MAINTENANCE FREQUENCY

Regular servicing must be carried out by trained personnel and a comprehensive inspection performed
annually or every 500,000 cycles, whichever is sooner.
DISCONNECT AIR SUPPLY
CAUTION - Never use solvents or other harsh chemicals for cleaning the non-metallic parts of the tool.
These chemicals may weaken the materials used in these parts.

5.2 NOSE EQUIPMENT

Nose assemblies need to be serviced at weekly intervals or every 5,000 cycles. Hold some stock of all internal
components of the nose assembly and nose pieces, they need regular replacement.
Disconnect the air supply
Remove the complete nose assembly using the procedure described in section 3.1.
Inspect all components. Any worn or damaged parts must be replaced by a new part.
Particularly check wear on the Jaws (1g).
Clean all parts and apply moly lithium Grease (07992-00020) to jaws (1g) and taper bore of jaw guide (1f).
Assemble according to fi tting instructions in section 3.2.

5.3 DAILY SERVICING

Before use, check the tool, hose and couplings for air leaks and oil leaks. If damaged, remove the tool from
service and replace aff ected items with new parts.
If there is no fi lter on the pressure regulator, bleed the airline to clear it of accumulated dirt or water before
connecting the air hose to the tool. If there is a fi lter, drain it.
Check that the nose equipment (1) is correct for the rivet to be placed and that it is fi tted properly.
Check that the stroke of the tool meets the minimum specifi cation (ref. 2.1).
The mandrel collector (3) must fi tted to the tool.
Check that the air chamber is fully tightened onto the tool body.

5.4 WEEKLY SERVICING

Check the tool, hose and couplings for air leaks and oil leaks. If damaged, remove the tool from service and
replace aff ected items with new parts.
For full servicing, troubleshooting and maintenance instructions please refer to the Service Manual
Nr. 07900-09408 for the XT1 and 07900-09409 for the XT2.
For Safety Data relating to the grease and oil used in this tool please refer to the Service Manual
Nr. 07900-09408 for the XT1 and 07900-09409 for the XT2.

5.5 PROTECTING THE ENVIRONMENT

Assure conformity with applicable disposal regulations. Dispose all waste products at an approved waste
facility or site so as not to expose personnel and the environment to hazards.
14