Indoor Water Heater Installation Venting Examples; Interior View - Navien NPE-180A2 Installation Manual

Condensing water heaters
Hide thumbs Also See for NPE-180A2:
Table of Contents

Advertisement

Hart & Cooley Polyflue™ (Certified to ULCS636)
2PF-90 or 3PF-90 (2" or 3" 90° Elbow)
2PF-45 or 3PF-45 (2" or 3" 45° Elbow)
2PF-T or 3PF-T (2" or 3" Tee)
2PF-HVST or 3PF-HVST (2" or 3" Birdscreen)
Z-Flex® Z-DENS (Certified to UL1738 and
ULCS636)
2ZDE_87 or 3ZDE_87 (2" or 3" 87° Elbow)
2ZDE_45 or 3ZDE_45 (2" or 3" 45° Elbow)
2ZDTT or 3ZDTT (2" or 3" Tee)
2ZDES or 3ZDES (2" or 3" Birdscreen)
The following stainless steel (AL29-4C) vent
components can be used as terminations:
Duravent FasNSeal® (Certified to UL1738 and
ULCS636)
FSELB9003 (3" 90° Elbow)
FSELB8803 (3" 88° Elbow)
FSELB4503 (3" 45° Elbow)
FST3 (3" Tee)
FSBS3 (3" Birdscreen)
Heat Fab Saf-T Vent® EZ Seal (Certified to
UL1738 and ULCS636)
9314(LR) or 9314TERM (3 " 90° Elbow)
9311 (3" 45° Elbow)
9390TEE (3" Tee)
9392 (3" Birdscreen)
Z-Flex® Z Vent (Certified to UL1738 and ULCS636)
2SVEEWCF0390 (90° Elbow)
2SVEEWCF0345 (45° Elbow)
2SVSTTF03 (3" Tee)
Only the termination models listed
Note
above are approved for use with this
appliance.
Only terminations of the same
manufacturer as the vent system
must be used.
Refer to the vent manufacturer's
instructions for detailed installation
procedures and guidelines.
54
Installing the Water Heater
Indoor Water Heater Installation
Venting Examples
The following are some possible indoor venting
options:
Two-Pipe Sidewall Venting

[Interior View]

1 2 " ( 3
Exhaust Gas
[Exterior View]
Intake Air
Exhaust Gas
i n .
m ) m
0 0 m
Intake Air

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Npe-210a2Npe-240a2Npe-150s2Npe-180s2Npe-210s2Npe-240s2

Table of Contents