CAUTION
This water heater has a built-in control to
limit the exhaust temperature to 149°F. As
a result, the Navien water heater can be
vented with Schedule 40 PVC.
In high temperature applications, the
exhaust temperature can exceed 149°F
(65°C). In that case, you must use Schedule
40/80 CPVC or Approved Polypropylene/
Stainless Steel in the USA or Type BH
Special Gas Vent Class IIB (CPVC) or Class
IIC (Polypropylene/SS) that conforms to
ULC-S636 in Canada.
When using 2 in. vent, if the exhaust
temperature exceeds 149°F (65°C), CPVC
pipe (field supplied) must be used for the
first 3 feet of equivalent pipe length. For
systems using 3 in. vent, the first 5 in. of
length must be CPVC pipe.
The following polypropylene vent components are
approved for use with this appliance:
Duravent PolyPro® SW (Rigid) (Certified to
ULCS636)
2PPS-xxx (2") or 3PPS-xxx (3")
Duravent PolyPro® (Flexible) (Certified to
ULCS636)
3PPS -FLEXxx (3")
2PPS-FAM or 3PPS-FAM (2" or 3" Rigid-to-Flex
Male Adapter)
2PPS-X3L (2" to 3" Increaser)
Centrotherm Innoflue® SW (Rigid) (Certified to
UL1738 and ULCS636)
ISxx02xx (2") or ISxx03xx (3")
Centrotherm Innoflue® (Flexible) (Certified to
UL1738 and ULCS636)
IFVL02xxx (2") or IFVL03x xx (3")
IFSFC02 or IFSFC03 (2" or 3" Rigid-to- Flex Male
Adapter)
ISEI0203 or ISIA0203 (2" to 3" Increaser)
Hart & Cooley Polyflue™ SW (Rigid) (Certified to
ULCS636)
2PF-xx (2") or 3PF-xx (3")
Z-Flex® Z-DENS SW (Rigid) (Certified to UL1738
and ULCS636)
2ZDxx (2") or 3ZDxx (3")
52
Installing the Water Heater
The following stainless steel vent components are
approved for use with this appliance:
Duravent FasNSeal® (Rigid) (Certified to UL1738
and ULCS636)
FSA-PVC3 (3" PVC to FasNSeal Appliance Adapter)
FSxxxxx03 (3")
Duravent FasNSeal® (Flexible) (Certified to
UL1738 and ULCS636)
FSASMM-PP-2 (2" PP-to-FasNSeal adapter)
FSFLEX-02 (2")
Heat Fab Saf-T Vent® EZ Seal
9301PVC (3" PVC/CPVC Outlet Boiler Adapter)
93xx (3")
Z-Flex® Z Vent
2SVSTTA023 (2" x 3" Appliance Adapter)
2SVEPSCF030X (Straight Pipe)
2SVEEWCF0390 (90° Elbow)
2SVEEWCF0345 (45° Elbow)
Only the vent pipe models listed
Note
above are approved for use with this
appliance.
Do not mix pipe, fittings, or
joint methods from different
manufacturers.
Proper appliance adapters must be
used when using polypropylene or SS
vent pipe.
Refer to the vent manufacturer's
instructions for detailed installation
procedures and guidelines.