13. Once the CO
or offset values have been
2
confirmed, apply the included conversion stickers
to show that the appliance has been converted
to natural gas. Place this labels adjacent to the
rating plate as shown in Figure 11.
This unit has been
Converted to Natural Gas /
Cet appareil a ete converti au Gaz Naturel
Ori ce Size / Injecteur:
Min. 4.8 mm to Max. 7.5 mm
Inlet Gas Pressure / Pression d'entrée du gaz:
Min. 3.5 to Max. 10.5 inches WC
Manifold Gas Pressure /
Pression à la tubulure d'alimentation:
Min. -0.03 to Max. -0.96 inches WC
BTU Input / Debit calori que:
Max. 199,900 BTUh - Min. 13,300 BTUh
Conversion Kit No.: NAC-N240
This water heater was converted on
______/______/______ to ____________ gas
with Kit No. ________________________
by _________________________________
_________________________________
(name and address of organization making
this conversion, who accepts responsibility
for the correctness of this conversion)
Figure 11. Proper Placement of Gas Conversion Labels
Manifold Gas Pressure ratings can
Note
change due to updated orifice
sizes. Please confirm new manifold
pressures approved by CSA before
production of gas conversion
labels.
This unit has been
Converted to Propane fuel /
Cet appareil a ete converti au Propane
Ori ce Size / Injecteur:
Min. 3.9 mm to Max. 5.65 mm
Inlet Gas Pressure / Pression d'entrée du gaz:
Min. 8.0 to Max. 13.0 inches WC
Manifold Gas Pressure /
Pression à la tubulure d'alimentation:
Min. -0.02 to Max. -0.96 inches WC
BTU Input / Debit calori que:
Max. 199,900 BTUh - Min. 13,300 BTUh
Conversion Kit No.: NAC-L240
Setting the Operation Mode
1. Press and hold the Menu button (
Back button (
) simultaneously for 3 seconds
and then select 4. Special Operations.
2. Press the Up button (
(
) to switch between the special operation
modes. Press the OK button (
parameter or to run a special operation mode.
Item
Set the water heater to run in the
1. Normal
normal mode.
Set the water heater to run in
2. 1
MIN
the 1-stage minimum operation
st
mode.
Set the water heater to run in
3. 1
MAX
the 1-stage maximum operation
st
mode.
Set the water heater to run in
4. 2
MIN
the 2-stage minimum operation
nd
mode.
Set the water heater to run in
5. 2
MAX
the 2-stage maximum operation
nd
mode.
3. Press the Back button (
previous screen or menu.
) and the
) or the Down button
) to select a
Description
) to return to the
Appendixes