Internal Recirculation Mode - Navien NPE-180A2 Installation Manual

Condensing water heaters
Hide thumbs Also See for NPE-180A2:
Table of Contents

Advertisement

Internal Recirculation Mode ("A2" Model
Only)
To use the internal recirculation mode:
1. Connect the water supply.
2. Set the 2-way valve inside the water heater to
"INT. "
3. Press the Menu button (
menu and select 1. Recirculation Setting >
3. Internal Recirculation by pressing the OK
button ( ).
) to access the Main
For more information about the
Note
Recirculation settings, refer to "6.4.1
Setting the Recirculation Mode" on
page 83.
Internal Recirculation is available
only on A2-type models.
Model Step 1 Step 2
A2-
type
CAUTION
Do not remove the cap on the recirculation inlet
fitting if the Internal Recirculation Mode is used.
The following diagram shows the internal
recirculation flow for pre-heating:
Primary Heat Exchanger
Buffer
Secondary Heat Exchanger
Tank
2-Way
Check Valve
Valve
Open
Hot Water
Supply

[Internal Recirculation Mode]

Step 3
Always On N/A
Int.
Intelligent N/A
Recirc
Schedule
Weekly
Set
Flow
Sensor
Circulation
Pump
Water
Adjustment
Valve
Domestic Water
Supply
Installing the Water Heater
27