(AL4_1) Electric wiring box memory fault.
It is not possible to store the number of "scale removal cycles".
HOME SPA model: the "alarm", "tepidarium", "hammam" and "calidarium" keys flash from
white to blue.
BASE AND DREAM model: not available
(AL5) Drainage solenoid valve and/or level sensor fault.
This may occur during the initial phase of the Turkish bath, if the sensor is blocked or if
the drainage solenoid valve is obstructed; it may also occur during the draining phase
of the scale removal cycle.
HOME SPA model: the "alarm" and "hammam" keys flash from white to blue.
BASE AND DREAM model: the "hammam" key flashes from white to blue for 3 seconds.
The function (Turkish bath or scale removal cycle) is interrupted.
(AL6) Filling solenoid valve and/or level sensor fault.
This may occur during the initial phase of the Turkish bath or during the function. The
cause may be a blocked sensor, an obstructed filling solenoid valve or lack of water.
It may also occur during the final draining phase of the scale removal cycle.
HOME SPA model: the "alarm" and "calidarium" keys flash from white to blue.
BASE AND DREAM model: the "hammam" key flashes from white to blue for 60 seconds.
The function (Turkish bath or scale removal cycle) is interrupted.
(AL7) Temperature not reached in the shower unit.
This may occur during the Turkish bath, due to a faulty heating element. Or, if the initial
temperature is lower than 25 °C and the function is active for 5 minutes, the probe does not
measure a temperature increase of at least 5 °C (e.g. the shower unit door is open).
BASE-DREAM-HOME SPA model: the "alarm" key flashes from white to blue.
(AL13) Activation of the safety thermostat.
This may occur during the Turkish bath.
HOME SPA model: "alarm" and "tepidarium" keys flash from white to blue for approx. 5
seconds and it will not be possible to start the function; if instead the alarm appears when
the function is in progress, it will be interrupted.
BASE AND DREAM model: the "Turkish bath" key flashes from white to blue for approx. 7
seconds; it will not be possible to start the function; if instead the alarm appears when the
function is in progress, it will be interrupted.