Simple Setting Mode

■Simple setting mode
<Operation>
[Simple setting mode (hysteresis mode)
In simple setting mode, the set value, hysteresis and delay time can be changed while the current value is
displayed (main display).
(1) Press and hold the SET button between 1 and 3 seconds in measurement mode. [SEt] is displayed on
the main display. When the button is released while in the [SEt] display, the current pressure value is
displayed on the main display, [P_1] or [n_1] is displayed on the sub display (left) and the set value
(flashing) is displayed on the sub display (right).
(2) Change the set value with the UP or DOWN button, and press the SET button to set the value. Then, the
setting moves to hysteresis setting. (The snap shot function can be used. (Refer to page 86))
(3) Press the UP or DOWN button to change the set value.
(The snap shot function can be used. (Refer to page 86))
(4) Press the SET button for less than 2 seconds to complete the OUT1 setting.
OUT2 setting is displayed on the sub display. Continue with the setting the OUT2.
Press and hold the SET
to measurement mode.
1: Selected items (1) to (3) become valid after pressing the SET button.
2: After enabling the setting by pressing the SET button, it is possible to return to measurement mode by pressing the SET button for 2
seconds or longer.
3: When the output mode of OUT 2 (refer to page 55) is set to error output or output OFF, the simple setting mode cannot be used.
button for 2 seconds or longer to complete the setting. The product will return
-50-