Specification; Specifications (Isa3) - SMC Networks ISA3 Series Operation Manual

Digital gap checker pressure switch
Hide thumbs Also See for ISA3 Series:
Table of Contents

Advertisement

Specification

■Specifications (ISA3)

Model
Applicable fluid
Rated distance range
Displayable/settable range
(Distance reference)
Min. display unit
(Distance reference)
Rated pressure range
Displayable range
3
(Pressure value)
Repeatability
Temperature characteristics
o
(Reference: 25
C)
Hysteresis
Rated pressure range
Setting pressure range
Min. display/setting unit
Repeatability
Temperature characteristics
o
(Reference: 25
C)
Hysteresis mode
Window comparator mode
Withstand pressure
Detection nozzle
Current flow
Used as switch output
device
Used as IO-Link device
Current consumption
Protection
Switch output
Max. load current
Max. applied voltage
Residual voltage
Short circuit protection
Display
ISA3-F
0.01 to 0.03 mm
0 to 60
1
1
0.005 mm or less
0.010 mm or less
0 to variable
(Default: 3)
5 L/min
2-screen (3-screen display available: sub display, 4 digits x 2)
Main display: 4 digits, 7-segments 2-colour (Orange/Green)
Sub display: 9 digits (Upper 9 digits, 4 digits, 3 digits 11-segments,
ISA3-G
Dry air (Filtered through a 5 μm filter)
0.02 to 0.15 mm
2
10 to 300
1
100.0 to 200.0 kPa
-20.0 to 220.0 kPa
0.010 mm or less
0.015 mm or less
0 to variable (Default: 20)
0.0 to 200.0 kPa
-20.0 to 220.0 kPa
0.1 kPa
±0.5%F.S.±1 digit
±2%F.S.
Variable from 0
600 kPa
1.5
8
12 L/min
24 VDC±10% with 10% voltage ripple or less
18 to 30 VDC, including ripple (p-p) 10%
25 mA or less
Polarity protection
Select from NPN or PNP open collector output
10 mA
30.0 V
1 V or less (at 10 mA)
Provided
7-segments for other)
-15-
2
About this product
ISA3-H
0.05 to 0.30 mm
2
2
30 to 500
0.020 mm or less
0.030 mm or less
7
22 L/min
No.PS※※-OMW0009-A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Isa3-fIsa3-gIsa3-h