5.2.2 Thermocouple Input Data Type/Format

The SP-016 supports extended configuration and provides factory calibration. All data values are returned as 32-bit
floating point values.
7
Smart
Sensor
Sensor
Writable
0

5.2.2.1 Data Type

The 4-bit Data Type field determines the type of data of the specific sensor.

5.2.2.2 Factory Calibrate

Factory calibration is used on the SP-016 process inputs. Clearing this bit will disable the factory calibration values.

5.2.2.3 Sensor Writeable

The writable bit is cleared, indicating that the sensor values may not be overwritten.

5.2.2.4 Smart Sensor

Refer to the Smart Sensor Device Interface documentation.

5.2.3 Thermocouple Input Configuration

7
Available
Assigned
0

5.2.3.1 Sensor Type / Range

Sensor Type
0x00
0x01
0x02
0x03
0x04
0x05
0x06
0x07
0x08
0x09
Thermocouple Input Data Type/Format
6
5
Factory
Reserved
Calibrate
0
?
Thermocouple Input Configuration
6
5
Apply
Scaling
*
?
Sensor Input Type (Range)
Type J
Type K
Type T
Type E
Type N
Reserved
Type R
Type S
Type B
Type C
4
3
0
4
3
Lock
Sensor Type (Range)
?
0x20
0x20
0x20
0x20
0x20
0x20
0x20
0x20
0x20
2
1
Data Type
0x06 == FLOAT
2
1
See Below
Measurement Type
Temperature (oC)
Temperature (oC)
Temperature (oC)
Temperature (oC)
Temperature (oC)
Temperature (oC)
Temperature (oC)
Temperature (oC)
Temperature (oC)
0
0