Rssi Digital (Agc) - Nokia NSW-5 Series Service Manual

Cellular phone
Table of Contents

Advertisement

NSW-5
Service Software Instructions
RSSI Digital (AGC)... command
Activation
Alt, T, D, H or L
Starts Automatic Gain Control calibration. This means Received Signal
Strenght indicators in digital mode.
The next automatic selections are made when this tuning function is acti-
vated:
EEPROM DAC values is shown and the measurement is started by
pressing Meas button. Measurement is done in eleven steps:
1. User is requested to put signal generator input level –95 dB and fre-
quency 879.030 MHz
2. Measurement with input level is executed
3. User is requested to put signal generator input level –85 dB and fre-
quency 879.030 MHz
4. Measurement with input level is executed
5. User is requested to put signal generator input level –75 dB and fre-
quency 879.030 MHz
6. Measurement with input level is executed
7. User is requested to put signal generator input level –65 dB and fre-
quency 879.030 MHz
8. Measurement with input level is executed
9. User is requested to put signal generator input level –55 dB and fre-
quency 879.030 MHz
10. Measurement with input level is executed
11. The AGC tuning dialog will be updated when previous steps are done
Page 34
Status Bar Text
Open the Tuning AGC dialog box
– Active Unit = RX
– Operation Mode = Continuous digital
– Selected band
– Channel 301 (low) or 500 (high )
– Power level 2
E Nokia Mobile Phones Ltd.
PAMS Technical Documentation
Issue 1 10/00

Advertisement

Table of Contents
loading

Table of Contents