LASER CLASS 730i/720i/710 Chapter 4: Maintenance and Service
No.
Tx or Rx
##0290
[TX
##0295
[TX
##0670
[TX
##0671
[RX
##0672
[TX
##0673
[RX
##0674
[TX
##0675
[RX
##0705
[TX
##0711
[TX
##0750
[TX
##0751
[TX
##0752
[TX
##0753
[TX
##0754
[TX
##0755
[TX
##0757
[TX
##0758
[TX
Definition
]
After transmitting MPS, a signal other than PIN, PIP,MCF,
RTP, or RTN was received
]
For the auto alarm notification function, the other party does not
have an NTT remote maintenance function
]
In V.8 late start, the V.8 ability was detected in DIS from the
other party and, in response, CI was transmitted; however, the
procedure failed to advance, causing a T1 time-over condition
]
In V.8 call arrives, the procedure fails to advance to phase 2 after
CM detection, causing a T1 time-over condition
]
In V.34 transmission, the procedure fails to move from phase 2
to phase 3 and later, causing a T1 time-over condition
]
In V.34 reception, the procedure fails to move from phase 2 to
phase 3 and later, causing a T1 time-over condition
]
In V.34 transmission, the procedure fails to move from phase 3
or phase 4 to a control channel or later, causing a T1 time-over
condition
]
In V.34 reception, the procedure fails to move from phase 3 or
phase 4 to a control channel or later, causing a T1 time-over
condition
]
In CHT transmission, DCN was received after detecting NACK
]
In CHT transmission, REJ was received after transmission of an
image signal
]
In ECM transmission, no significant signal can be received after
transmission of PPS-NULL, and the allowed number of
procedure signal re-transmissions was exceeded
]
In ECM transmission, a signal other than MCF, PPR, or RNR
was received after transmission of PPS-NULL
]
In ECM transmission, DCN was received after transmission of
PPS-NULL
]
In ECM transmission, the allowed number of procedure signal
re-transmissions was exceeded or a T5 time-over (60 sec)
condition occurred after transmission of PPS-NULL
]
In ECM transmission, the allowed number of procedure signal
re-transmissions was exceeded after transmission of PPS-NULL
]
In ECM transmission, no significant signal can be received after
transmission of PPS-MPS, and the allowed number of procedure
signal re-transmissions was exceeded
]
In ECM transmission, DCN was received after transmission of
PPS-MPS
]
In ECM transmission, the allowed number of procedure signal
re-transmissions was exceeded or a T5 time-over (60 sec)
condition occurred after transmission of PPS-MPS