Technical specifications
Mechanical ambient conditions
The following table shows the mechanical ambient conditions in the form of sinusoidal
vibrations.
Table 4- 1
Frequency range
5 ≤ f ≤ 8.4 Hz
8.4 ≤ f ≤ 150 Hz
Tests of mechanical ambient conditions
The following table provides important information with respect to the type and scope of the
tests of ambient mechanical conditions.
Table 4- 2
Tests of mechanical ambient conditions
Test of ...
Vibration
Shock
10
Mechanical ambient conditions
ET 200SP with BusAdapter
BA 2×FC
3.5 mm amplitude
1 g constant acceleration
Test standard
Note
Vibration test
Type of vibration: Frequency sweeps with a rate of change
according to
of 1 octave/minute.
IEC 60068-2-6 (Sinus)
Duration of vibration: 10 frequency sweeps per axis at each of three
vertically aligned axes
Shock, tested
Type of shock: Half-sine
according to
Shock intensity: 150 m/s
IEC 60068-2-27
Direction of shock: 3 shocks in each direction (+/-) at each of three
vertically aligned axes
5 Hz ≤ f ≤ 8.4 Hz, 3.5 mm constant amplitude
8.4 Hz ≤ f ≤ 150 Hz, 1 g constant acceleration
peak value, 11 ms duration