3. Detailed Settings Function for Air-to-Water

Detailed settings for Air-to-Water
<Procedure of CZ-RTC5>
[
]
START
1
Keep pressing the
simultaneously for 4 or more seconds.
The "Maintenance func" screen appears on the LCD
display.
Maintenance func
0. ECONAVI info.
1. Outdoor unit error data
2. Service contact
3. RC. setting mode
Sel.
Page [
2
Press the
or
If you wish to see the next screen instantly, press the
or
button.
Select "13. Air-to-Water unit" on the LCD display and
press the
button.
Maintenance func
10. Set elec.consumption
11. Set touch key
12. Check touch key
13. Air-to-Water unit
Sel.
Page [
List of detailed setting items for Air-to-Water
Item code
Item
02
Mode select
04
Heating curve function use
05
Existence of External device
06
Optional thermo sensor use
07
2-way Valve
* Setting at shipment
20:30 (THU)
,
and
buttons
20:30 (THU)
] Confirm
button to see each menu.
20:30 (THU)
] Confirm
No.
0000
0001
0002
0000
0001
0000
0001
0002
0000
0001
0002
0003
0000
0001
3
Press the
or
If you wish to see the next screen instantly, press the
or
button.
Select "Air-to-Water settings" on the LCD display and
press the
button.
Air-to-Water unit
Air purge
Pump speed setup
Cancel int.heater alarm
Air-to-Water settings
Sel. [
4
The "Air-to-Water settings" screen appears on the LCD
display.
Select the "Code no." by pressing the
button for changes.
Air-to-Water settings
Code no.
02
Sel.
5
Select the "Set data" by pressing the
button.
Select one of the "Set data" by pressing the
button.
Then press the
6
Select the "Unit no." by pressing the
button and press the
The "Exit Air-to-Water unit settings and restart?"
(Air-to-Water settings-end) screen appears on the LCD
display.
Select "YES" and press the
Air-to-Water unit
Air purge
Exit Air-to-Water unit
Pump speed setup
settings and restart?
Cancel int.heater alarm
Air-to-Water settings
YES
Sel. [
Setting data
Description
No *
Tank
Air Conditioning
No
YES *
No *
Yes
Yes (No alarm) (installation manual undescribed)
No *
Remote controller
Remote sensor
External thermo
Normal Open
Normal Close
*
5 - 7
Air-to-Water Indoor Unit
button to see each menu.
20:30 (THU)
]
Set
or
20:30 (THU)
Set data
0000
Next
or
button.
or
button.
button.
20:30 (THU)
NO
]
Set
or
5