NOTE: If the Pump does not prime properly, which may
occur with heavier, high viscosity fluids, increase the air
pressure with the RAM DOWN Air Regulator (AK).
NOTE: If fluid is forced out around the top wiper, ram
pressure is too high; decrease the air pressure with the
RAM UP Air Regulator (AJ).
NOTE: Ram pressure adjustments are carried out using
the dual REGULATOR Control Knobs (AC, AE) inside
the Pneumatic Logic Panel (G). The upper regulator
knob controls the downward pressure of the ram, and
the lower regulator knob controls the upward pressure
of the ram. See F
. 5 on page 14.
IG
22. After closing the bleed valve, return PUMP NO. 1
and PUMP NO. 2 REGULATOR Control Knobs (AC,
AE) to the normal Pump pressure setting.
23. Open the air motor ball valves.
24. Open the ball valve in the outlet manifold from
Pump No. 1 and 2.
25. Remove the waste containers, clean up any spilled
material, and dispose of the waste material
properly.
26. Press the PUMP RESET Pushbutton to restore the
system to operation.
27. Check that the following lights are lit:
SYSTEM PRESSURIZED
AIR PRESS ON
RAM READY
PUMP READY
309028ZAT

Daily System Startup

This procedure is normally provided by the integrator.

System Shutdown

This procedure is normally provided by the integrator.

Stopping the System

To stop the system, close the Main Air Shutoff Valve (P)
(see F
. 15) to the Supply Unit.
IG

Restarting the System

To restart the system, perform the following steps:
1. Open the Main Air Shutoff Valve (P) to the Supply
Unit (see F
. 15).
IG
2. At the Junction Box Panel (H), press the PUMP
RESET Pushbutton, which restarts the Pumps after
the Pumps were turned off. See F
F
. 15
IG
Operation
. 6 on page 16.
IG
P
Ti20917a
33