3.
Wipe clean the rollers and glass in the scanner body. Rotate the rollers to clean the entire
surface.
4.
Wipe clean the rollers and glass in the underside of the ADF door. Rotate the rollers to clean
the entire surface.
5.
Using a clean, dry cotton swab, brush away any dust on the double feed detection sensors.
6.
Close the scanner when you're finished.

Replacing the Reverse (Separation) Roller

The roller will wear out and is designed to be a user-replaceable part. A worn roller can cause
documents to feed in skewed at an angle, or multiple pages to feed at the same time. Before
replacing the roller you should clean it as excessive dust on the roller will make it appear worn and
smooth. You cannot properly diagnose a worn roller until you have cleaned it. You should generally
replace the roller between 80,000 and 100,000 scans.