A A / / C C S S y y s s t t e e m m C C h h a a r r g g i i n n g g a a n n d d A A P P U U E E n n g g i i n n e e S S t t a a r r t t - - u u p p P P r r o o c c e e d d u u r r e e s s
10. Select A A l l t t e e r r n n a a t t o o r r C C a a p p a a c c i i t t y y . Choose the alternator model installed:
a. 65 Amps (Default)
b. 120 Amps
11. Select E E n n g g i i n n e e C C o o o o l l i i n n g g Option:
a. S S t t a a n n d d a a r r d d : The APU engine cooling system is connected to the truck cooling system. Sensor WT2 is mounted on
the pre-cooler coil.
b. S S t t a a n n d d a a r r d d + + A A r r c c t t i i c c (Default): The APU engine cooling system is connected to the truck cooling system. The
Arctic Option is installed. Sensor WT2 is mounted on the adapter tube in the coolant return line.
c. C C l l o o s s e e d d L L o o o o p p : The APU engine cooling system is not connected to the truck cooling system. Closed Loop
Cooling Tank is installed. Sensor WT2 is disconnected or not installed.
12. Enter U U n n i i t t S S e e r r i i a a l l N N u u m m b b e e r r : Record the 10-digit TriPac EVOLUTION unit serial number from the unit identification
plate.
13. Enter U U n n i i t t I I D D : Enter a unique unit ID number. The truck number is commonly used. Can be any combination of six
letters and numbers. It will help identify data logger downloads
14. Select U U p p d d a a t t e e U U n n i i t t S S e e t t u u p p :
a. Setup information will be saved.
b. Controller will restart so selections will take effect.
c. TK Monitor will lose connection and must be restarted.
P P r r o o g g r r a a m m m m a a b b l l e e F F e e a a t t u u r r e e S S e e t t u u p p
N N o o t t e e : : The Battery Voltage Restart Value and Real Time Clock should always be set.
The TriPac EVOLUTION system allows customizing of many operating features. Refer to Diagnostic Manual TK 55739,
Section 3, Software for more information about programmable features. Changes directed by the customer should be
made at this time.
15. Restart TK Monitor. Select the P P r r o o g g r r a a m m m m a a b b l l e e S S e e t t u u p p screen.
92
Figure 52. Unit Setup Screen Shown
IMPORTANT STEPS FOR EACH TRIPAC EVOLUTION INSTALLATION
RCS1668
TK 55676-19-IM-EN