R R i i s s k k o o f f I I n n j j u u r r y y ! !
T T o o p p r r e e v v e e n n t t t t h h e e A A P P U U f f r r o o m m s s t t a a r r t t i i n n g g u u n n e e x x p p e e c c t t e e d d l l y y , , s s e e t t a a l l l l e e l l e e c c t t r r i i c c a a l l c c o o n n t t r r o o l l s s t t o o t t h h e e O O F F F F p p o o s s i i t t i i o o n n B B E E F F O O R R E E
c c o o n n n n e e c c t t i i n n g g w w i i r r e e s s t t o o b b a a t t t t e e r r y y . .
1. Route the heater fuel pump harness down to the fuel pump and cut the wires to the correct length.
a. Strip wire ends, slide on rubber sealing boots, attach pin terminals securely with crimping tool.
b. Insert pin terminals into connector body until they lock in place.
N N o o t t e e : : The pump is not polarity sensitive. The wires can be installed in either location of the connector body.
c. Snap locking cover closed on connector body.
d. D D O O N N O O T T connect the fuel pump harness to the fuel pump at this time. The fuel pump harness will be attached