Wiring a power connection

To use the 2-pin 3.5 mm mini-Phoenix connector with a 12 VDC-compliant power supply, the incoming
PWR and GND cables from the external source must be connected to their corresponding locations on
the connector (FIG. 4).
1. Insert the PWR and GND wires on the terminal end of the 2-pin 3.5 mm mini-Phoenix cable. Match
the wiring locations of the +/- on both the power supply and the terminal connector.
2. Tighten the clamp to secure the two wires. Do not tighten the screws excessively; doing so may strip
the threads and damage the connector.
3. Verify the connection of the 2-pin 3.5 mm mini-Phoenix to the external 12 VDC-compliant power
supply.
PWR +
GND -
To the Integrated Controller
FIG. 4
2-pin mini-Phoenix connector wiring diagram (direct power)

Using the 4-pin mini-Phoenix connector for data and power

Connect the 4-pin 3.5 mm mini-Phoenix (female) captive-wire connector to an external NetLinx device
as shown in FIG. 5.
To the Integrated Controller's
AXlink/PWR connector
Top view
FIG. 5
Mini-Phoenix connector wiring diagram (direct data and power)
NI-3101-SIG Signature Series NetLinx Integrated Controller
Connections and Wiring
Power Supply
To the external AXlink device
Top view
13