Approved Venting Method 3: Internal or External Masonry Chimney System 
 
 
 
 
 
 
 
 
Chimney liner cross‐sectional 
area (Length x Width) must be 
no larger than twice the cross‐ 
sectional area of the flue collar 
(2 x 28.27 in
= 56.55 in
chimney liner is larger than 
2
56.55 in
, relining with a 5.5" 
or 6.0" liner is required 
 
 
Masonry Thimble with 
proper clearance to 
combustibles 
 
Follow the rules listed above concerning maximum permissible flue liner size; installing this unit on masonry chimneys 
exceeding 56.55 in
Use three sheet metal screws at each single wall chimney connector joint (check manufacturer's 
recommendations when double wall chimney connector is used). 
Drill three holes in the flue collar of the unit and attach the chimney connector to the unit using sheet metal 
screws (holes should be pre‐drilled in flue collar from factory). 
Avoid  numerous  elbows  and  excessive  horizontal  runs  as  both  will  lead  to  poor  draft  and  increased  creosote 
accumulation.    Horizontal  runs  of  chimney  connector  must  never  exceed  4.0  ft.  and  the  overall  length  of  the 
chimney connector must not exceed 8.0 ft. with single wall black connector pipe. If necessary to run longer than 
8.0 ft. of chimney connector pipe, double wall black chimney connector pipe must be used. 
A tight seal at the thimble is crucial for proper unit performance and to create a safe installation.  Use the proper 
adapter designed for connecting single or double wall chimney connector to a masonry thimble. 
Have existing masonry chimneys inspected for safety and proper clearances to combustibles before putting them into 
service; a qualified chimney sweep can perform this inspection. 
External masonry chimneys often suffer cold downdrafts and poor draft performance even when they meet the 
cross‐sectional area rules.  In this case, a 6.0" insulated liner may be necessary. 
 
 
 
Please Note: Installation diagrams are for reference purposes only and are not drawn to scale, nor meant to be used as plans 
for each individual installation.  Please follow all venting system requirements, maintain the required clearances to 
combustibles, and follow all local codes. 
14
INSTALLATION 
2
).  If 
in cross‐sectional area will result in decreased draft and the potential for poor unit performance. 
10 ft. 
The 10‐3‐2 Rule: The chimney system 
must terminate 3.0 ft. above the point 
where its centerline passes through the 
roof AND the chimney must terminate 
2.0 ft. above any part of the dwelling 
within a 10 ft. radius of the chimney. 
 
 
 
Chimney Connector 
(Single or Double Wall) 
 
Ash Cleanouts must 
have an airtight seal to 
prevent weak draft. 