Save Packaging Material - American Dynamics SpeedDome Optima LT Installation Manual

Camera dome indoor pendant mounting structure
Hide thumbs Also See for SpeedDome Optima LT:
Table of Contents

Advertisement

Power cable requirements
Table 3 shows the maximum cable distance for
several worst-case low line voltages between
various indoor power sources and the indoor
SpeedDome Optima LT camera dome. These
distances are for Sensormatic composite cables,
which use 18
ac power wires.
AWG
Table 3. Power cable requirements
Indoor Dome
AC Power Source
28 VA
Transformer
5604-0006-01
50 VA
Transformer
5604-0044-01
1-position SensorNet
RJ1SNUD
1-position SensorNet
RJ1SNUD-1
6-position SensorNet
Indoor J-Box
RJ6SN
Universal Transformer
0300-0914-01
Universal Transformer
0300-0914-03
SPEEDDOME OPTIMA LT INDOOR PENDANT MOUNTING STRUCTURE
INSTALLATION GUIDE
Worst-Case
Meters
Low Line V
(Feet)
117
130 (425)
100
80 (250)
90
60 (200)
117
160 (525)
100
100 (325)
90
60 (200)
117
160 (525)
100
100 (325)
90
80 (250)
240
160 (525)
200
100 (325)
180
80 (250)
117
210 (675)
100
130 (425)
90
80 (250)
240
210 (675)
200
130 (425)
180
80 (250)
117
130 (425)
100
100 (325)
90
60 (200)
240
160 (525)
200
100 (325)
180
80 (250)
SensorNet Line Termination
SensorNet communication protocols require line
termination. Accessing slide switch S1 through the
hole in the top of the dome, terminate the dome
furthest from the video controller or junction box by
moving the switch to the "terminated" position. All
other domes along the line must be unterminated.
Manchester and RS-422 protocols do not require
line termination.
Setting the Camera Address
At the top of the dome are rotary switches SW1,
SW2, and SW3 used to set the dome address.
Protocol address ranges are as follows:
SensorNet
Manchester
RS-422
For example, for address 107, set SW3 to 1, SW2
to 0 (black dot), and SW1 to 7.
Compatibility with the VM96 Controller
If using a VM96 controller, the controller must be
Version 5.2 or higher.
Power-Up Routine
After power is connected to the dome, the dome
performs a homing routine. During the homing
process, the camera will pan and then either:
• Go to the start point of the "apple peel" pattern,
or
• If powered up once before, to the last position in
memory.
Once the camera stops, the camera is online and
is ready to be controlled.
Synchronizing Domes
To prevent picture rolling when switching from
camera to camera, all domes can be synchronized
to the ac source. A V-phase adjustment at the
control console enables the dome to sync to any
line phase.

Save Packaging Material

Should the camera dome need to be sent to a
repair center, use the packaging that the dome was
shipped in.
4 of 10
1-255
1-64
1-99
8200-0181-04, REV. B