Ipsdu8 Dome Alarms; Certification And Regulations; Table 5-2 Indoor And Outdoor Alarm Details; Table 5-3 Certification And Regulations - American Dynamics IP SpeedDome Ultra 8 Configuration And User's Manual

American dynamics speeddome ultra 8: user guide
Hide thumbs Also See for IP SpeedDome Ultra 8:
Table of Contents

Advertisement

Technical Specifications

IPSDU8 Dome Alarms

Table 5-2 Indoor and Outdoor alarm details

Input Alarms
(From Cable
Harness)
Output
Indoor
Alarms
3x Open Collector 12V max.
(To Cable
100 mA max
Harness)
Outdoor
1x Relay Contact 1A at
30VDC or
0.3A at 125VAC

Certification and Regulations

Table 5-3 Certification and Regulations

Category
Specification
Safety
UL/EN/IEC 60950-1 1
EMC
USA
Canada
Europe
Australia /
New Zealand
RoHS
Complies with European directive 2002/95/EC
5-4
Quantity and Type
1x TTL
3x TTL
st
Edition
FCC Part 15b 107 & 109, class A
ICES-003/NMB-003 class A
EN55022:2006 class A
EN61000-3-2:2000 + A2:2005
EN61000-3-3:1995 + A1:2005 + A2:2005
EN50130-4:1995 + A1:1998 + A2:2003
AS/NZS CISPR 22, class A
Name
Alarm_In_1
Alarm_In_2 to Alarm_In_4
Alarm_Out_1 to Alarm_Out_3
Details
Hardware
Connectivity
To ENCODER only
To DOME only
From DOME only
Configuration and User Guide

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents