result in clicks in the audio.
For more information on 48kHz clock, see sections 2.1C and 2.3.
3.2E Output ADAT Tracks to AI-1
If the BRC is in Edit mode (the EDIT button is lit), and the DIGITAL
I/O button is pressed a third time when the Digital Input is set to
"ADAT", (or if it is pressed a second time when set to "AES/EBU" or
"S/PDIF"), you may select the source tracks that will output to the
AI-1. When the DIGITAL I/O button is pressed again, you may
select the AI-1 destination, which can be either "ADAT",
"AES/EBU" or "S/PDIF". You may also set the destination clock
rate for the AI-1 to either 48kHz or 44.1kHz, thus performing sample
rate conversion.
To route ADAT tracks to the AI-1 from the BRC:
1. Press the EDIT button (the EDIT button LED will go on to
indicate you are in Edit mode);
2. Press the DIGITAL I/O button;
3. Use the UP/DOWN buttons to select "ADAT" as the Digital
Input you wish to use as a source for recording;
4. Press the DIGITAL I/O button twice;
The display will show the following:
All the record and input track LEDs will no longer reflect the
record/monitor status. The TRACK INPUT LEDs will now reflect
the current source tracks to be output to the AI-1.
5. Use the TRACK SELECT buttons to select the tracks to output to
the AI-1;
• To select a single source track, press the desired TRACK SELECT
button. The track will now be enabled and its green LED will be
Select tracks to
output to AI-1
28