E Output Adat Tracks To Ai-1 - Alesis AI-1 Reference Manual

Digital interface and sample rate converter
Table of Contents

Advertisement

result in clicks in the audio.
For more information on 48kHz clock, see sections 2.1C and 2.3.

3.2E Output ADAT Tracks to AI-1

If the BRC is in Edit mode (the EDIT button is lit), and the DIGITAL
I/O button is pressed a third time when the Digital Input is set to
"ADAT", (or if it is pressed a second time when set to "AES/EBU" or
"S/PDIF"), you may select the source tracks that will output to the
AI-1. When the DIGITAL I/O button is pressed again, you may
select the AI-1 destination, which can be either "ADAT",
"AES/EBU" or "S/PDIF". You may also set the destination clock
rate for the AI-1 to either 48kHz or 44.1kHz, thus performing sample
rate conversion.
To route ADAT tracks to the AI-1 from the BRC:
1. Press the EDIT button (the EDIT button LED will go on to
indicate you are in Edit mode);
2. Press the DIGITAL I/O button;
3. Use the UP/DOWN buttons to select "ADAT" as the Digital
Input you wish to use as a source for recording;
4. Press the DIGITAL I/O button twice;
The display will show the following:
All the record and input track LEDs will no longer reflect the
record/monitor status. The TRACK INPUT LEDs will now reflect
the current source tracks to be output to the AI-1.
5. Use the TRACK SELECT buttons to select the tracks to output to
the AI-1;
• To select a single source track, press the desired TRACK SELECT
button. The track will now be enabled and its green LED will be
Select tracks to
output to AI-1
28