For example, for R1 = R2 = 1K, the system will go in:
Tamper state if the resistance falls below 800 ohms.
l
Ready state if the resistance is between 800 and 1,500 ohms.
l
Alarm state if the resistance is between 1,500 and 12,000 ohms.
l
Tamper state if the resistance is above 12,000 ohms.
l
Note
Resistor tolerance 1% or better.
l
Capable of up to 100 ohms resistance.
l
3.8.2.3
Triple Balanced
R2
ALARM
TROUBLE
R1
N.C.
State at input terminals
Short circuit
R1 ohms
R1 + R2 ohms
R1 + R3 ohms
R1 + R2 + R3 ohms
Open circuit
Acceptable values for for R1, R2, and R3 are:
R1 = 1K
l
R2 = 1K
l
R3 = 3K.
l
The electrical bands are indicated below:
0
Tamper
<
Ready
800 Ω
42
Honeywell MAXPRO Intrusion MPIP2000U/3000U Series
R3
N.C.
Message to the system
Tamper
Ready
Alarm
Trouble
Mask condition (trouble when system is
disarmed; alarm when system is armed)
Tamper
<
Alarm
<
1,800 Ω
2,500 Ω
Trouble
<
Mask
4,500 Ω
800-23044 Rev.  A draft_11
Ohm
<
Tamper
10,000 Ω