Honeywell MAXPRO MPIP2000U Series Installation And Setup Manual page 35

Integrated security systems
Table of Contents

Advertisement

Honeywell MAXPRO Intrusion MPIP2000U/3000U Series
# Item
H Vplex BUS 1
I
IB2 BUS 1
J
IB2 bus 1
K LTE Cell
Radio
L For future use.
M Ethernet
N Relay 2
O Relay 1
P Triggers
Q Jumpers for low-voltage triggers. For details, see Wiring Outputs on
page 48.
R Zones 9, 10
800-23044 Rev.  A draft_11
Terminal
or
Connect with
connector
+
V-Plex bus 1 +
V-Plex bus 1 –
+12V AUX1 12 VDC supply terminal for devices
connected to IB2 bus 1.
0 VDC supply terminal for devices connected
to IB2 bus 1.
C
IB2 bus C
D
IB2 bus D
Quick connect plug for IB2 BUS 1 (can be used for
module stacked on top of main board; quick connect
cable is included).
USB and
Connectors for the 4G/LTE module
PWR/IO
WAN
Network with internet connection to the
cloud.
NC
Normal Closed terminal, output relay 2
C
Common terminal, output relay 2
NO
Normal Open terminal, output relay 2
Relay 2 is only available on the MPIP3000 series.
NC
Normal Closed terminal, output relay 1
C
Common terminal, output relay 1
NO
Normal Open terminal, output relay 1
Spare 0 VDC connector.
For outputs. For details, see Wiring Outputs on page 48.
Can also be used for a self-activating bell. For details, see
Installing a Self-Activating Bell (SAB) on page 47.
For zones (sensor contact inputs). Can be used for 2-wire
smoke sensors or as standard burglary zones.
For details, see Wiring Inputs (Zones) on page 39.
Installation and Setup Guide
35

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Maxpro mpip3000u seriesMaxpro mpip2100uMaxpro mpip3000u