Section 2: Configuration
March 2014
Configuring scaled variable using a field communicator
From the HOME screen, enter the Fast Key sequence
Device Dashboard Fast Keys
1.
Follow the screen prompts to configure Scaled Variable.
a.
Configuring scaled variable using AMS Device Manager
1.
Right click on the device and, select Configure.
2. Select the Scaled Variable tab and click the Scaled Variable button.
3. Follow screen prompts to configure Scaled Variable
a.
Configuring scaled variable using a local operator interface
Refer to
Operator Interface.
Figure 2-12. Configuring scaled variable using a local operator interface
2.8.3

Re-mapping device variables

The re-mapping function allows the transmitter primary, secondary, tertiary, and quaternary
variables (PV, 2V, 3V, and 4V) to be configured as desired. The PV can be remapped with a field
communicator, AMS Device Manager, or a LOI. Variables (2V, 3V, and 4V) can only be re-mapped
via Field Communicator or AMS Device Manager.
Note
The variable assigned to the primary variable drives the 4-20mA (1-5 Vdc) output. This value can
be selected as Pressure or Scaled Variable. The 2, 3, and 4 variables only apply if HART burst
mode is being used.
22
Select Linear under Select Scaled data options.
Select Linear under Select Scaled data options.
Figure 2-12 on page 22
VIEW CONFIG
ZERO TRIM
UNITS
RERANGE
LOOP TEST
DISPLAY
EXTENDED MENU
EXTENDED MENU
EXIT MENU
2, 1, 4, 7
for instructions to configure Scaled Variable using a Local
EXTENDED MENU
CALIBRAT
DAMPING
TRANSFER FUNCT
SCALED VARIAB
SCALED VARIAB
ASSIGN PV
TAG
ALARM SAT VALUES
PASSWORD
SIMLATE
HART REV
BACK TO MENU
EXIT MENU
Reference Manual
00809-0100-4108, Rev BA
SCALED VARIAB
VIEW SCALED
CONFIG SCALED
CONFIG SCALED
BACK TO MENU
EXIT MENU
Configuration

Advertisement

Table of Contents
loading

This manual is also suitable for:

G1s22a1b4e5q4p0021

Table of Contents