9 MAIN POSITIONING CONTROL

9.2.4 1-axis fixed-dimension feed control

In "1-axis fixed-dimension feed control" (" Da.2 Control method" = fixed-dimension
feed 1), one motor is used to carry out fixed-dimension feed control in a set axis
direction.
In fixed-dimension feed control, any remainder of the movement amount designated in
the positioning data is rounded down if less than that required for control accuracy to
output the same amount of pulses.
Reverse direction
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Operation chart
In 1-axis fixed-dimension feed control, the address ( Md.29 Current feed value) of
the current stop position (start point address) is set to "0". Positioning is then
carried out to a position at the end of the movement amount set in " Da.5
Positioning address/movement amount".
The movement direction is determined by the movement amount sign.
0
0
Positioning
Designated movement
start
amount
Movement direction for
a negative movement amount
0
0
Stop position
Movement direction for
a positive movement amount
9 - 29
MELSEC-A
" Md. 29 Current feed
value" is set to "0" at
the positioning start
0
Forward direction

Hide quick links: