Table 5-74. E1 Performance Monitoring Status Screen Hot Keys - ADTRAN Total Access 1248 Installation And Maintenance Practice

Octal t1 ima dslam
Hide thumbs Also See for Total Access 1248:
Table of Contents

Advertisement

Total Access 1248 Octal T1 IMA DSLAM Installation and Maintenance Practice
Table 5-73. E1 Performance Monitoring Status Screen Codes (Continued)
Code
Definition
CV-P
Code Violations
CV-L
Code Violations
ES-L
Errored Seconds
The E1 Performance Monitoring Status screen hot keys are defined in

Table 5-74. E1 Performance Monitoring Status Screen Hot Keys

Hot Key
Description
Backward(2hrs/15min PM)
B
Clear PM Stats
C
Forward(2hrs/15min PM)
F
Next Port
N
Previous Port
P
Select Port
S
5-108
Description
This code indicates an occurrence of either a CRC-6
error or frame bit error on the path.
This code indicates an occurrence of either a CRC-6
error or frame bit error on the line.
This code indicates seconds with either a bipolar
violation or a CRC-6 error on the line.
Function
This hot key is used to display performance monitoring
statistics for the last 2 hours, in 15 minute intervals.
This hot key is used to clear the performance monitoring
statistics.
This hot key is used to display performance monitoring
statistics for the next 2 hours, in 15 minute intervals.
This hot key is used to display the next port.
This hot key is used to display the previous port.
This hot key is used to select a specific port.