DOK-MOTOR*-IDYN*A*EXPD-IB05-EN-P
Rexroth MAD and MAF Motors in EX px d Design acc. to ATEX Directive 2014/34/EU
12

Maintenance / repair

Maintenance
Increase availability with regular preventive maintenance measures. Notice
the information in the maintenance schedule of the machine manufacturer
and the following details regarding maintenance measures and intervals for
the motor.
WARNING
Basically, any work on live parts is forbidden.
Before starting work that has to be carried out, observe the important
safety regulations according to DIN VDE 530, such as releasing the
power; securing against restarting; ensuring that the system is not under
power; grounding and short-circuiting; and covering or fencing off neigh‐
boring parts that are under power.
Ensure that the measures mentioned above cannot be repealed before
the work is completed.
Measure
Only applicable to MAF motors:
Check the coolant system for
proper functioning.
Only applicable to MAD motors:
Check the functioning of the fan
and the air circulation.
Check the mechanical and elec‐
trical connections.
Check the air hoses for motor
scavenging device for proper
seat and tightness.
Check the machine for smooth
running, vibrations and bearing
noise.
Remove dust, chips and other
dirt from the motor housing,
cooling fins and the connections.
Tab. 12-1:
Maintenance measures
Bosch Rexroth AG
Maintenance / repair
Over pressure encapsulated device!
Danger of explosion and electrocution by live
parts of more than 50 V!
Interval
According to the specifications in the machine
maintenance plan, but at least every 1000 ope‐
rating hours.
According to the specifications in the machine
maintenance plan, but at least every 1000 ope‐
rating hours.
According to the specifications in the machine
maintenance plan, but at least every 1000 ope‐
rating hours.
According to the specifications in the machine
maintenance plan, but at least every 1000 ope‐
rating hours.
Note: An error message of the control device re‐
garding pressure loss in the over pressure encap‐
sulation can be a sign of deterioration of the radial
shaft sealing ring on the motor.
According to the specifications in the machine
maintenance plan, but at least every 1000 ope‐
rating hours.
According to the guidelines in the machine main‐
tenance plan or according to the pollution severty,
at least every 1,000 operating hours.
59/69