Sony STR-DA2800ES Service Manual page 38

Multi channel av receiver
Hide thumbs Also See for STR-DA2800ES:
Table of Contents

Advertisement

STR-DA2800ES
HISTORY MODE
The state that the set is used is memorized.
Note: Even if "MEMORY CLEAR MODE" is performed, the backup data
of "HISTORY MODE" is not cleared.
Initialize by performing "SHIPMENT MODE".
Procedure:
1. While pressing the [MEMORY/ENTER] and [MUSIC] but-
tons, press the [
] button to turn on the power and "HIS-
?/1
TORY" is displayed.
HISTORY
2. Each time the [M] or [m] buttons of remote commander is
pressed, the item is switched in order as follows.
(Displayed characters/values in the following fi gure are ex-
ample)
COUNT
Protector generation
total count
T
H M
State of headphone in
Operating time until
first time protector
generating first time
protector (active
standby is contained)
M
H M
Main on time until
generating first time
protector
PROT
Factor of generating first
time protector
Sound field in first time
protector
Input selector in first
time protector
Input mode in first time
protector
Input under lock in first
time protector
Stream under input in
first time protector
Releasing method:
Press the [
] button to turn off the main power.
?/1
38
CONF
Channel information in
first time protector
HEADPH
EQ setting value in first
time protector
(front high bass)
VOL:
Volume in first time
protector
MUTING:
Muting in first time
protector
F B
.
EQ setting value in first
time protector
(front bass)
F T
.
EQ setting value in first
time protector
(front treble)
C B
.
EQ setting value in first
time protector
(center bass)
C T
.
EQ setting value in first
time protector
(center treble)
S B
.
EQ setting value in first
time protector
(surround bass)
S T
.
EQ setting value in first
time protector
(surround treble)
F B
.
F T
.
EQ setting value in first
time protector
(front high treble)
F
/
Level collection value
each channel in first
time protector
(front L/front R)
C
/
Level collection value
each channel in first
time protector
(center/subwoofer)
S
/
Level collection value
each channel in first
time protector
(surround L/surround R)
B
/
Level collection value
each channel in first
time protector
(surround back L/
surround back R)
H
/
Level collection value
each channel in first
time protector
(front high L/front high R)
TEMP:
Temperature status
T
H15M
Total operation time
after the shipment
M
H15M
Main zone power on
time after the shipment
REBOX: 05
Number of times of the
power on after the
shipment

Advertisement

Table of Contents
loading

Table of Contents