Installation/Separation - Wolf CGS-2-14/120L Installation Instructions Manual

Hide thumbs Also See for CGS-2-14/120L:
Table of Contents

Advertisement

Handling
The gas condensing centre is secured to the transportation
pallet at 4 points.
The front cylinder casing has to be removed in order to trans-
port the gas condensing centre.
This reveals the transportation screws on the floor panel of the
cylinder and the two transportation handles on the cylinder.
Remove the transportation screws at the back of the cylinder.
Dismantling the CGS-2L/R side cylinder casing:
- Open control unit flap (1)
- Remove both screws on the lower front panel (2)
- Remove lower front panel (3)
- Remove all four screws from the side cylinder casing (4)
- Open out the side casing panels and release both casing pins (5)
- Pull side casing down to remove it (6)
Refit in reverse order
Removing the side panels makes the entire appliance unstable.
Take care during transportation and pipework installation without the casing.
After filling the system, check the tightness of the connection lines between heating module A and cylinder B.
20

10. Installation/separation

Fig.: Front transportation handles/locking screws
Fig.: Back transportation handles/locking screws
Transportation
handles
SW 10
Transportation handles
SW 10
3064816_201804