Upgrading from an Existing Access Point 2000

Upgrading from an Existing Access Point 2000
CAUTION: If you have an existing Access Point 2000 and want to install
the RoamAbout R2 in its place, please refer to the following important
information.
You cannot interchange the Access Point 2000 with the RoamAbout R2 without replacing
the power supplies and, if applicable, the power injector and redundant power supply. You
must use the power supply, power injector, and the redundant power supply shipped with
the RoamAbout R2.
You must replace the Access Point 2000 power supply (5652041-xx or 5652042-xx)
with the RoamAbout R2 power supply (5652054-xx) at the RoamAbout R2.
You must replace the Access Point 2000 redundant power supply (5652042-xx), on the
wired side, with the RoamAbout R2 power supply (5652054-xx).
To determine if your Access Point contains a redundant power supply:
a) Remove the power supply from the Access Point.
b) If there is still power, you will need to locate the redundant power supply on the
wired side. Replace it with the RoamAbout R2 power supply (5652054-xx).
You must replace the following Access Point power injectors:
— 8917544-01
— 8917544-02
— 8917544-03
with 8917544-05 (preferred) or 8917544-04.