Connect Message; Add Party Message; Signaling Protocol Profile - 3Com CoreBuilder 7000 Operation Manual

Atm switches
Hide thumbs Also See for CoreBuilder 7000:
Table of Contents

Advertisement

Signaling — External Links
107
CALL-PROCEEDING Suppression" on page 208 in the Management
Guide).
The CONNECT signaling message is sent in response to the SETUP

CONNECT Message

command. It indicates that the receiving side of the connection has
accepted the requirements and the call setup is complete. The CONNECT
message also includes the VPI/VCI message element.

ADD PARTY Message

The ADD PARTY message sets up point-to-multipoint connections
between a source root station and the destination leaf stations. After a
root connection is established between the root station and one of the
leaf stations via the SETUP message, additional connections between the
root station and the other leaf stations are established by the ADD PARTY
message. The ADD PARTY message contains the same QoS and traffic
parameters that the SETUP message used to set up the root connection.
In the CoreBuilder 7000 family ATM switch, the signaling protocol profile
Signaling Protocol
of a port defines the role that the port plays in the signaling dialog with
Profile
its attached ATM device. The profile can be either network or user. When
the CoreBuilder 7000 family ATM switch port is connected to an
end-station or edge device, the CoreBuilder 7000 family ATM switch port
is normally defined as network (Net). When the CoreBuilder 7000 family
ATM switch is connected to another CoreBuilder 7000 family ATM
switch, the port of the CoreBuilder 7000 family ATM switch with the
highest Network Prefix is assigned the network profile and the port of the
other CoreBuilder 7000 family ATM switch is assigned the user (Usr)
profile.
One difference between the two profiles is that the user port initiates the
ATM connection by sending a SETUP message, but the network port
defines the VPI/VCI pair for the ATM connection. Thus, if an ATM user
sends a SETUP message to a CoreBuilder 7000 family ATM switch port,
the VPI/VCI message element is left empty. The switch proposes a VPI/VCI
pair for the connection and sends it back to the user as part of the CALL
PROCEEDING message or, in case there is none, as part of the CONNECT
message. The CONNECT message is sent by the switch to the user only
after the switch has received a CONNECT message from the call
destination.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Corebuilder 7000 series

Table of Contents