Sscop Configuration Parameters; Managing Signaling Protocol Parameters - 3Com CoreBuilder 7000 Operation Manual

Atm switches
Hide thumbs Also See for CoreBuilder 7000:
Table of Contents

Advertisement

116
C
5: E
HAPTER
STABLISHING
SSCOP Configuration
Parameters
Managing Signaling
Protocol Parameters
ATM C
HANNELS
For stability, the timer No-Response should be greater than the timer
Keep-Alive and the timer No-Response should be greater than the timer
Poll. Timer No-Response and timer CC should be set to a value greater
than the round trip delay. The timer Idle may be considerably greater than
the timer Keep-alive.
Table 33 shows the SSCOP configuration parameter values.
Table 33 SSCOP Configuration Parameters
SSCOP
Parameter
Description
MaxCC
Maximum value for the state variable VT(CC),
corresponding to the maximum number of
transmissions of a BGN, END, or RS PDU
MaxPD
Maximum acceptable value for the state
variable VT(PD) before sending a POLL PDU
and resetting VT(PD) to zero
MaxSTAT
Maximum number of list elements
permissible in a STAT PDU
Window
Sequence number of the first SD or SDP PDU
not allowed by the receiver
Display AAL5 Control Statistics
For information on how to display AAL5 control statistics see "Display
AAL5-Layer Control Statistics" on page 244 in the Management Guide.
The following signaling protocol parameters can be displayed and
updated by management. Except where designated these parameters are
per port.

UNI (Q93B) signaling timers for all ports

UNI (Q93B) signaling protocol VPI/VCI configuration parameters

QSAAL signaling protocol timer values


SSCOP configuration parameters


Signaling protocol profile

Signaling protocol version

Call-proceeding message enable flag
For more information, see Chapter 7 in the Management Guide.
Default value
5
10
67
16