Data Plane; Introduction To The Data Plane - Huawei NE40E-X1 Hardware Description

Universal service router
Table of Contents

Advertisement

HUAWEI NE40E-X1 & NE40E-X2 Universal Service
Router
Hardware Description
Table 2-6 Indicators on the fan module
Indicator
FAN indicator

2.4 Data Plane

2.4.1 Introduction to the Data Plane

NPUs are key parts on the NE40E-X2 and are responsible for data processing and data switching
between PICs and NPUIs.
The procedure for data processing is as follows:
1.
2.
3.
4.
Issue 02 (2011-09-10)
Description
If the indicator is steady green, it indicates that the fan module works
normally.
The indicator is off when the fan module is unregistered, powered
off, or has a hardware fault.
If the indicator is steady red, it indicates that the fan module fails.
The IP packets sent from PICs and 2x10G interfaces on an NPU converge at a convergence
module.
The NP processes the IP packets.
The TM module performs traffic management on the IP packets.
The Fabric Interface Chip (FIC) performs IP packet switching.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2 NE40E-X2 Hardware Description
32

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ne40e-x2