Prem-I-Air PMSF09 Series Installation Manual

Prem-I-Air PMSF09 Series Installation Manual

Wall split type
Hide thumbs Also See for PMSF09 Series:

Advertisement

ROOM AIR CONDITIONER
INSTALLATION MANUAL
(WALL SPLIT TYPE)
For PMSF09/12/18 Series
Please read this installation manual completely
before installing the product.
When the power cord is damaged, replacement
work shall be performed by authorized personnel
only.
Installation work must be performed in accordance
with the national wiring standards by authorized
personnel only.
Contact the authorised service technician for
repair or maintenance of this unit.

Advertisement

loading

Summary of Contents for Prem-I-Air PMSF09 Series

  • Page 1 ROOM AIR CONDITIONER INSTALLATION MANUAL (WALL SPLIT TYPE) For PMSF09/12/18 Series Please read this installation manual completely before installing the product. When the power cord is damaged, replacement work shall be performed by authorized personnel only. Installation work must be performed in accordance with the national wiring standards by authorized personnel only.
  • Page 2: Table Of Contents

    CONTENTS SAFETY PRECAUTIONS..............2 INSTALLATION OF INDOOR AND OUTDOOR UNITS.......3 INSTALLATION INSTRUCTIONS............5 ELECTRICAL WORK ................9 TEST RUNNING................! WARNING Do not install, remove and reinstall the unit by yourself. Improper installation will cause water leakage, electrical shock, or fire. Please consult authorized dealer or specialist for the installation work.
  • Page 3: Safety Precautions

    SAFETY PRECAUTIONS The following should be always observed for safety: Be sure to read the following WARNING before installing the air conditioner. Be sure to observe the cautions specified here as they include important items related to safety. After reading this instructions, be sure to keep it together with the owners manual in a handy place for future reference.
  • Page 4: Installation Of Indoor And Outdoor Units

    INSTALLATION OF INDOOR UNIT AND OUTDOOR UNITS Read completely, then follow step by step. Indoor unit Do not expose the indoor unit to heat or steam. Select a place where there are no obstacles in front or around the unit. Make sure that condensation drainage can be conveniently routed away.
  • Page 5 Items packed with the unit Q ty Number Name of Accessories Installation Plate Wall plugs Self-tapping Screw A ST3.9X25 Seal Drain Joint Remote controller Self-tapping Screw B ST2.9X10 Remote controller holder Note: Except the above parts provided, the other parts needed during installation you must purchase.
  • Page 6: Installation Instructions

    INSTALLATION INSTRUCTIONS INDOOR UNIT INSTALLATION Fit the Installation Plate Correct orientation of Installation Plate 1. Fit the installation plate horizontally on structural parts of the wall with spaces around the installation plate. 2. If the wall is made of brick, concrete or the like, drill eight (8) 5mm diameter holes in the wall.
  • Page 7 3. Drainage Installation 1. Run the drain hose sloping downward. Do not install the drain hose as illustrated below. Do not put the hose Do not form a rise end into water Fig.7 2. When connecting extension drain hose, insulate the connecting part of extension drain hose with a shield pipe, do not let the drain hose slack.
  • Page 8 CAUTION Do not allow the piping to let out from the back of the indo or unit. Be careful not to let the drain hose slack. Heat insulated both of the auxil i ary piping. Be sure that the drain ho se is located at the lowe st side of the bundle. Loc ating at the upper side can cau se drain pan to overflow inside the unit.
  • Page 9 Drain joint installation Fit the seal into the drain elbow, then insert the drain joint into the base pan hole of outdoor unit, rotate 90 to securely assemble them. Connecting the drain joint with an Base pan hole of Drain joint Seal outdoor unit extension drain hose (Locally purchased),...
  • Page 10: Electrical Work

    To disconnect the couplings: Step 1: Shut down the A/C unit and unplug the electr i cal power cord from the wall outlet. Step 2: Wait five minute s for the line pressure be tween the indoor compressor unit and outdoor condensing unit to equalize. Step 3: Pull the male cou pling handle up and toward the mal e coupling to full back position.
  • Page 11 Cover Screw Fix the connection cable Fig.15 with cord clamp. Option B: 1. The connection cables of indoor and outdoor units have been connected to the terminals on the control board except the grounding wire(Y/G), only white plug connectors exposed. 2.
  • Page 12: Test Running

    Input Rated Amp Power supply Model (Switch/Fuse) 9000Btu/h 220-240V~ 50Hz 10000Btu/h 220-230V~ 60Hz NOTE: The supply voltage can not be less than the rate voltage of the air conditioner. CAUTION CAUTION CAUTION After the confirmation of the above conditions, prepare the wiring as follows: 1) Never fail to have an individual power circuit specifically for the air conditioner.