Panasonic LP-GS Series Serial Communication Command Manual page 138

Laser marker
Hide thumbs Also See for LP-GS Series:
Table of Contents

Advertisement

Name
Omit
Start row
or
Start column
Last row
or
Last column
Adjustment
item
X-movement
Y
Y-movement
Y
Z-movement
Y
Rotation
Y
movement
Laser power
Y
correction
Total data length
* Setting request data are variable length.
⿎ Example of command settings
Condition:
Adjustment No. = 0, Adjustment object = 2, Object group No. = 0, Start row = 2,
Last row = 3, Adjustment item = 0, X-movement = 0.1, Y-movement = -0.2, Z-movement = 0.3,
Rotation movement = 2.1, Laser power correction = -20
• Setting
Transmission data
• Readout
Transmission data
Response data
Condition:
Adjustment No. = 0, Adjustment object = 3, Object group No. = 0, Start column = 4, Last column = 4,
Adjustment Item = 1
• Setting
Transmission data
• Readout
Transmission data
Response data
138
Data
length
Data contents
[byte]
Max. 3*
"001"–"400"
Max. 3*
"0": Position/Power
1
"1": Mark OFF
Max. 8*
"-999.999"–"+999.999" [mm]
Max. 8*
Model
LP-GS051
LP-GS052
Max. 8*
LP-GS051-L
LP-RC350S
LP-RF200P
Max. 8*
"-180.000"–"+180.000" [°]
Max. 3*
"-50"–"+50" [+/-%]
Max. 60
It is the length including the separator ",".
[STX]
SRA
[STX]
SRA
[STX]
SRA
[STX]
SRA
[STX]
SRA
[STX]
SRA
Setting range [mm]
"-003.000"–"+003.000"
"-001.500"–"+001.500"
"+000.000" or omit
S
0,2,0,2,3,0,0.1,-0.2,0.3,2.1,-20
R
0
[CR]
000,2,0000,002,003,0,+000.100,
A
-000.200,+000.300,+002.100,-20
S
0,3,0,4,4,1
R
0
[CR]
A
000,3,0000,004,004,1
ME-LPGS-SR-5
Remarks
Enables the adjustment item for the
data at the row/column specified.
If you specify "1": Mark OFF, end
the data here. It is not necessary to
transmit the subsequent data including
a separator ",".
• Moves the coordinate of the
marking data in the range of rows/
columns specified.
• It is the movement for the
coordinate after executing Step &
repeat.
• Z-movement cannot be specified
with LP-GS051-L, LP-RC and LP-
RF series.
Corrects the laser power of the
marking data in the range of rows/
columns specified.
Specify the correction ratio in the
range of 100±50% relative to the laser
power for the object to which Step &
repeat applies.
[CR]
[CR]
[CR]
[CR]