3-10-3 Object marking specification: ENA

Sets whether or not to mark the object of the specified number or data in the object group.
⿎ Setting request data
Start
ENA
code
⿎ Readout request data
Start
ENA
code
⿎ Response data for readout
Start
ENA
code
⿎ Data description
Name
Object category
Object (group) No.
Marking ON/OFF
Total data length
* Setting request data are variable length.
⿎ Example of command settings
Condition:
Object category = 0, Object No. = 5, Marking ON/OFF = 0, Object No. = 6, Marking ON/OFF = 1
• Setting
Transmission data
Condition:
Object category = 0, Object No. = 5
• Readout
Transmission data
Response data
122
[Object category], [Object (group) No.],
S
[Marking ON/OFF]
(, [Object (group) No.], [Marking ON/OFF])
[Object category], [Object (group) No.]
R
[Object category], [Object (group) No.],
A
[Marking ON/OFF]
Data length
[byte]
"0": Object
1
"1": Object group
Max. 4*
"0000"–"1999"
"0": Marking OFF
1
"1": Marking ON
It is the length including the separator ",".
The maximum value that can be set to one object number or object group
Max. 8
number.
Max. 32 objects or object groups can be set at once.
[STX]
ENA
[STX]
ENA
[STX]
ENA
Max. 6-byte
8-byte
Data contents
S
0,5,0,6,1
[CR]
R
0,5
[CR]
A
0,0005,0
[CR]
ME-LPGS-SR-5
(Check sum)
End code
(Check sum)
End code
(Check sum)
End code
Remarks