Panasonic LP-GS Series Serial Communication Command Manual page 137

Laser marker
Hide thumbs Also See for LP-GS Series:
Table of Contents

Advertisement

Name
Omit
Laser power
Y
correction
Total data length
* Setting request data are variable length.
⿎ Example of command settings
Condition:
Adjustment No. = 0, Adjustment object = 1, Object group No. = 0, Target row = 2,
Target column = 3, Adjustment item = 0, X-movement = 0.1, Y-movement = -0.2, Z-movement = 0.3,
Rotation movement = 2.1, Laser power correction = -20
• Setting
Transmission data
• Readout
Transmission data
Response data
Condition:
Adjustment No. = 0, Adjustment object = 1, Object group No. = 3, Target row = 3, Target column = 3,
Adjustment item = 1
• Setting
Transmission data
• Readout
Transmission data
Response data
Reference
• When the adjustment item is set to Mark OFF, the subsequent data after X-movement do not exist in the response data
for readout.
⿎ Setting request data / response data for readout: when adjustment object is row or column
Start
Sub
SRA
code
command
Sub command is "S" for the setting request data and the initial setting "A" for the response data for readout.
⿎ Data description
Name
Omit
Adjustment
No.
Adjustment
object
Object group
No.
Data length
[byte]
Max. 3*
"-50"–"+50" [+/-%]
60
It is the length including the separator ",".
[STX]
SRA
[STX]
SRA
[STX]
SRA
[STX]
SRA
[STX]
SRA
[STX]
SRA
[Adjustment No. ], [Adjustment object], [Object group No.],
[Start row/column], [Last row/column], [Adjustment item],
[X-movement], [Y-movement], [Z-movement],
[Rotation movement], [Laser power correction]
Data
length
Data contents
[byte]
Max. 3*
"000"–"999"
"2": Row
1
"3": Column
Max. 4*
"0000"–"1999"
Data contents
S
0,1,0,2,3,0,0.1,-0.2,0.3,2.1,-20
R
0
[CR]
000,1,0000,002,003,0,+000.100,
A
-000.200,+000.300,+002.100,-20
S
0,1,3,3,3,1
[CR]
R
0
[CR]
A
000,1,0003,003,003,1
Max. 60-byte
ME-LPGS-SR-5
Remarks
Corrects the laser power of the
marking data in the range of
rows/columns specified.
Specify the correction ratio in
the range of 100±50% relative
to the laser power for the object
to which Step & repeat applies.
[CR]
[CR]
[CR]
(Check
sum)
Remarks
Specifies an object group number with
Step & repeat set.
End