Installation on Flat Roofs
or Freestanding Installation
Installing Freestanding Installation
Model SH
Installation height above
ground level
Required weight at 25°
Required weight at 45°
*1
Securing against slipping requires no additional attachment to roof.
*2
Securing against lifting requires additional attachment to roof or structure with wires or cables.
*3
Weights listed are the total of the insert weights and support slabs, per collector.
24
(with ballast weight inserts - for Model SH only)
Secure against slipping
ft.
<26
26 - 66
m
< 8
8 - 20
*3
lbs
712
1237
kg
323
561
lbs
1085
1863
kg
492
845
*1
Secure against lifting
66 - 328
<26
26 - 66
20 - 100
< 8
8 - 20
1764
342
800
155
2641
291
1198
132
*2
66 - 328
20 - 100
695
1049
315
476
560
827
254
375