Chapter 5 Emc Directive; Overview; Conforming Standards In The Emc Directive - Mitsubishi Electric GOT SIMPLE Series User Manual

Graphic operation terminal
Hide thumbs Also See for GOT SIMPLE Series:
Table of Contents

Advertisement

5
EMC DIRECTIVE
5.1

Overview

For the products sold in European countries, the conformance to the EMC Directive, which is one of the European Directives,
has been a legal obligation since 1996.
Manufacturers, who recognize that their products comply with the EMC Directive must declare that their products comply with
the Directives and put a CE mark on the products.
Sales representative in Europe
The sales representative in Europe is as shown below.
Company name: Mitsubishi Electric Europe BV
Address: Mitsubishi-Electric-Platz 1, 40882 Ratingen, Germany

Conforming standards in the EMC Directive

The GOT complies with the following standards in the EMC Directive.
Applied
Test standard
standard
EN61131-2: 2007
CISPR16-2-3
Radiated noise
IEC61000-4-2
Electrostatic immunity
IEC61000-4-3
Radiated electromagnetic field,
amplitude modulation
IEC61000-4-4
Fast transient burst noise
IEC61000-4-5
Surge immunity
IEC61000-4-6
Conducted RF immunity
IEC61000-4-8
Power supply frequency magnetic
field immunity
*1 The GOT is an open type device (designed to be integrated in equipment).
Make sure to install the GOT on a control panel.
This test item is conducted in the condition where the GOT is installed on a control panel and combined with the MITSUBISHI PLC.
*2 QP: Quasi-peak value, Mean: Average value
*3 This test item is conducted in the following conditions.
· 30 MHz to 230 MHz
QP: 40 dBμV/m (measured at 10 m)
· 230MHz to 1000MHz
QP: 47 dBμV/m (measured at 10 m)
Test details
Test for measuring electromagnetic emissions
*1
from the product
Immunity test in which static electricity is
*1
applied to the cabinet of the equipment
Immunity test in which an electric field is applied
to the product
*1
Immunity test in which burst noise is applied to
*1
the power cables and the signal lines
Immunity test in which lightening surge is
*1
applied to the product
Immunity test in which a noise inducted on the
*1
power cable and the signal lines is applied
Test for checking normal operations under the
circumstance exposed to the ferromagnetic field
noise of the power supply frequency (50/60 Hz)
Standard value
• 30 MHz to 230 MHz
*2*3
QP: 30 dBμV/m (measured at 30m)
• · 230MHz to 1000MHz
*2*3
QP: 37 dBμV/m (measured at 30m)
• Contact discharge: ±4 kV
• Aerial discharge: ±8kV
80 MHz to 1000 MHz: 10 V/m
1.4GHz to 2GHz: 3V/m
2.0GHz to 2.7GHz: 1V/m
(80% amplitude modulation at 1 kHz)
Power cable: 2 kV
Digital I/O: 1 kV
Analog I/O: 1 kV
Signal cable: 1 kV
• DC power type
Power cable (between cable and ground): ±0.5 kV
Power cable (between cables): ±0.5 kV
Data communication port: ±1kV
Power cable: 10V
Data communication port: 10V
30 A/m