Loop Signal Strength - Husqvarna Automower 210 C Technical Manual

Hide thumbs Also See for Automower 210 C:
Table of Contents

Advertisement

6.3 Loop signal strength

Below are the loop signal strength levels for the
respective Corridor width. The strength that the
Automower
®
follows varies from search to search. For
example, with Corridor width 6 set on the 02.71
260ACX (2010) mower program, the signal strengths
for the boundary loop varies between 255-286
The low strength is the one that the mower searches
for when it follows the boundary wire at maximum
distance. The higher strength is the one that the
mower searches for when it follows the loop at the
minimum distance.
When Automower
is set to follow the boundary wire or
®
the guide wire with the help of the Test IN function
(3-2-4), it follows the loop according to the low strength
on the loop signal, that is to say, at maximum distance
from the loop. Consequently, you should always use
the Test IN (3-2-4) function when testing whether the
set corridor width is appropriate.
Table 8: Strength on the loop signal at respective corridor widths.
Corridor width
Version 02.71 260 ACX (2010)
Version 02.70 220 AC, 230 ACX (2006-2010)
Version 02.62 Solar Hybrid, GSM (2008-2010)
Version 02.61 Solar Hybrid (2008-2010)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
6. TROUBLE SHOOTING
Boundary loop (min – max)
289 – 300
282 – 296
274 – 293
269 – 292
260 – 288
255 – 286
250 – 280
240 – 266
234 – 257
228 – 253
222 – 249
217 – 247
212 – 243
209 – 242
205 – 237
201 – 232
199 – 228
196 – 223
193 – 220
191 – 218
191 - 230 (only 260 ACX)
Guide wire
(min – max)
(-) 250 – 265
(-) 239 – 265
(-) 228 – 263
(-) 220 – 258
(-) 212 – 253
(-) 204 – 247
(-) 189 – 231
(-) 178 – 224
(-) 168 – 211
(-) 160 – 207
(-) 153 – 201
(-) 147 – 194
(-) 141 – 184
(-) 136 – 177
(-) 131 – 174
(-) 126 – 171
(-) 121 – 164
(-) 116 – 158
(-) 111 – 156
(-) 108 – 155
(-) 104 - 200 (only 260 ACX)
English - 113

Advertisement

Table of Contents
loading