Should the cables to and from an obstacle cross, the
Automower
can perceive it is outside the working
®
area despite being inside the working area. Besides,
if the obstacle is relatively large in relation to the
working area this can affect the mower within the
entire working area.
Obstacles within the working area that can be run into
should still be demarcated by the boundary wire even
though the function of the Automower
demand this. It will however make operations quieter
and significantly reduce wear on the Automower
Obstacles that can withstand a collision include large
trees, large kerbstones, swing frames, sandpits,
walls, thick bushes, etc.
Connector
If the supplied boundary wire is not long enough to
run all the way round the working area, an additional
wire can be spliced on using an original solderless
coupler (part number 501 98 02-01). The total length
of the boundary wire should not exceed 500 metres
(1600 ft), (250 metres (800 ft) for 210 C). For
installations where a longer boundary wire of up to
800 metres (2560 ft) is required, we recommend a
Signal amplifier (522 42 58-01), which is available as
an accessory.
To join the boundary wire: Insert both ends of the
wires into the connector. Then press down the button
on top of the connector. The button has been pressed
down fully when none of edges of the button can be
felt or seen on the connector.
Tip! The connector must be pressed together fully to
ensure functionality. A pair of pliers is recommended.
IMPORTANT INFORMATION
Twisted cables, or a screw terminal
(chock-block), insulated with insulation tape
is not a satisfactory splice. Soil moisture will
cause the conductors to oxidise and after a
while result in a broken circuit.

3.3 Guide wire

This section does not apply to 210 C.
3.3.1 Need of a guide wire
With the help of a guide wire Automower
and easily find the charging station by following the
guide wire instead of searching irregularly or by
following the boundary wire.
On 230 ACX, Solar Hybrid and 260 ACX it is possible
to install two guide wires, examples showing
installation with two guide wires can be found in
chapter 3.10 Installation examples, page 54 .
46 - English
3. INSTALLATION
®
does not
.
®
can quickly
®