Figure 17 Sealed Bulkhead Diver Mate Plug Connector - Siemens DigiTRON Series Installation, Operation And Maintenance Manual

Single connectors
Table of Contents

Advertisement

Installation of sealed bulkhead
Referring to Figure 17, inspect 'O' ring grooves for damage and debris prior to installation of 'O' rings.
Apply a small amount of DC4 grease to the interface 'O' rings and install on the connector, fit
connector to interface ensuring correct orientation (unless otherwise stated ensure the key is at the
12-o'clock position).
Apply a spot of Loctite 243 to the threads of the cap head mounting screws and tighten to a torque
of 10-12Nm (7.38 – 8.85 lbf.ft) for metal to metal flange contact.
'O' SEALS
FITTED
'O' SEALS
'O' SEALS
(NOT FITTED)
NOT FITTED
Bulkhead connectors with pigtail wires terminated should be treated with care, especially around the
termination area and the termination area should not be bent. Excessive force should not be used
to pull the wires. The connector should not be held or carried using the terminated wires.
Care must be taken to protect the tails on installation. The tails must be fed through the bulkhead
without damage or kinking occurring. The connectors must be installed so that once they are fitted
in place the tails will not be obstructed or snagged.
Unrestricted
diver connectors
(FITTED)
Figure 17
Sealed bulkhead diver mate plug connector
M6
GRUB
SCREW
W
MOUNTING
MOUNTING SCREWS
SCREWS
Document No: IOM-002
Issue Date:
24/09/2020
Revision:
6
Page:
30 of 42