Configuring The Output - TDK-Lambda Genesys Series User Manual

Optional interface: lxi compliant lan
Hide thumbs Also See for Genesys Series:
Table of Contents

Advertisement

11.1.3. Examples of Alternative Forms of SCPI Command
For a command is described as:
[SOURce]:VOLTage:PROTection:LEVel <nn.nn|MAX >
The following are correct forms of the same command:
SOURCE:VOLTAGE:PROTECTION:LEVEL MAX
:VOLTAGE:PROTECTION:LEVEL MAX
:VOLT:PROTECTION:LEVEL MAX
:VOLT:PROT:LEV MAX
:volt:prot:lev max
The following are invalid forms of the command and will cause an error:
:CURRENT:PROTECTION:STATE
:CURRENT: PROTECTION:STATE MAX
:CURR:PROTEC:STATE ON
CURR:PROT:STAT ON

11.2. Configuring the Output

11.2.1. Set the Voltage Limit
This command sets the voltage limit. When the power supply is running in constant-voltage mode, this
will be it's output voltage.
The voltage limit, rounded to four digits, may be viewed on the supply front panel by pressing and releasing
the PREView button.
Syntax:
Parameter:
over-
Example:
Query:
Errors:
11.2.2. Set the Current Limit
This command sets the current limit. When the power supply is running in constant-current mode, this
will be it's output current.
The current limit, rounded to four digits, may be viewed on the supply front panel by pressing and releasing
the PREView button.
Syntax:
Parameter:
Example:
Query:
Errors:
(longest form of command)
(SOURCE is optional)
(Abbreviate VOLTAGE)
(Shortest form of command)
(Small letters acceptable)
(missing parameter, MAX or number)
(no spaces in command)
(PROTEC is not complete abbreviation)
(Colon required if SOURCE skipped)
[SOURce]:VOLTage[:LEVel][:IMMediate][:AMPLitude] <nn.nn>
is volts, the acceptable range is:
<nn.nn>
from 5% more than the under-voltage (UVL) setting to 5% less than the
voltage protection (OVP) setting
:
VOLT 18.5
:
will return
in the example
VOLT?
18.5
(this may be different than the actual output voltage)
SYSTEM:ERROR? may return errors including:
-222, "Data out of range"
+301, "PV above OVP"
+302, "PV below UVL"
[SOURce]:CURRent[:LEVel][:IMMediate][:AMPLitude] <nn.nn>
is amps, from zero to 5% more than the current rating
<nn.nn>
:CURR 172.75
will return
in example
:CURR?
172.75
(this may be different than the actual output current)
SYSTEM:ERROR? may return errors including:
-222, "Data out of range"
38

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents